PAC Time

The unit VIKA IV-2 is designed to determine the normal density, timing, setting and determining the thickness of crust of cement grout. Thickening time of cement grout or mortar component is determined from data on setting time. The characteristics of this process is the time to start setting time and setting to the end. When the cement slurry reaches the state corresponding to the beginning of setting, it can not be properly packed and sealed. Final set corresponds to the onset of hardening test.

Since the beginning of setting concrete mix undergoes a significant loss of yield. In the concrete mixture is also observed a false setting. It notably in cases where the curing occurs in the presence of partially dehydrated gypsum. Udo-boukladyvaemost mixture can not recover the additional mixing. The false setting may be due to the formation of excessive amounts of ettringita – especially in the presence of some inhibitors. Needle VIKA IV-2 is designed to determine the normal density, timing, setting and determining the thickness of the cement crusts test.

In this method, the time to start setting is fixed when the needle goes into the dough to a depth of 25 mm and the time before the end of the setting – when the needle does not penetrate much into cement paste. Specifications: Diameter of needle, mm: 1,1 0,04 Needle length, mm: 50 Diameter of the pistil, mm: 10 0,02 length of pistil, mm: 60 Weight moving rod with a needle or a pestle, g: 300 2 Scale, mm: 1 Height ring to cement paste, mm: 40 0,5 Overall dimensions: 140h160h245 The following accessories are includes: unit Vick IV-2 in the assembly manual. 'Chemical' – a wide range of chemical products, equipment and appliances. Chemical products for industrial and laboratory supplies, organic and inorganic acids and bases, salts with organic and inorganic acids, organic solvents, indicators. Equipment necessary for normal functioning of a modern laboratory: nefteanaliza equipment, chromatographic and electrochemical analysis equipment to analyze the physical and chemical parameters of all media, as well as laboratory equipment to support the selection and training samples, weighing equipment, thermostat and heating equipment, mixing devices, electrical laboratory equipment. Hydrometer ADB-1, EBE-2 Viscometer, Cone spreadability of the CD-1, CTC Laboratory LGR-3 mixer LMR-1, OM-Drain 2, pycnometer P-1, instrument Vick, BM-6, SVC-01, KC-3 KC-5, SNS-2, Stalagmometr ST-1, PKN-unit 2, cylinder stability CA-2, STF-acid-OEDF acid, lime, borax, 5 water, 10 water, Mel, caustic soda technical, Polyelectrolyte MIC-402 and Silica gel IBC, KSKG, SHSMG, Sulfatsell-2 Sulfonol, Activated carbon, mud powder, barite, dolomite weighting, CSSC, Neonol, saponified tall pitch VPRG reagent (dry hydrolyzed polyacrylonitrile) Reapon, Sial, FHLS-M, GL-1 Graphite, Graphite lubricants, greases, thread and surfactant consignment note PKD-515, Wetting OP-7 OP-10, Penta-465, CMC, PAC-B, PAC-N SNPH, Vikor corrosion inhibitor.

Published in: General

Comments are closed.